- 产品品牌:霍尼韦尔Honeywell
- 产品型号:SCXL004DN
- 制作工艺:生产
- 输出信号:MV
SCXL004DN
Precision Compensated, Low Pressure Sensors
January 1998/043
?0 - 4 In. H2O
?Very Low Pressure
Resolution
?Precision Temperature
Compensation
?Low Noise
?Calibrated Zero and Span
?High Impedance for
Low Power Applications
APPLICATIONS
?Air Flow
?Respirators
?HVAC
ELECTRICAL CONNECTIONS
Pin 1. Temperature Output (+)
Pin 2. VS
Pin 3. Output (+)
Pin 4. Ground
Pin 5. Output (-)
Pin 6. Temperature Output (-)
Note: The polarity indicated is for
pressure applied to port B
The SCXL series sensors provide a
very cost effective solution for pressure
applications that require high accuracy over
very low operating pressure ranges.
These internally calibrated and
temperature compensated sensors were
specifically designed to provide an accurate
and stable output over a 0癈 to 50癈
temperature range.
This series is intended for use with noncorrosive,
non-ionic working fluids such
as air and dry gases.
The output of the bridge is ratiometric to
the supply voltage and operation from any
D.C. supply voltage up to +18V is
acceptable.
GENERAL DESCRIPTION
EQUIVALENT CIRCUIT
Bottom View
Scale: 1cm
?inch
SCXL004DN
Precision Compensated, Low Pressure Sensors
January 1998/043
Aubinger Weg 27, 82178 Puchheim, Germany
Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33
http://www.sensortechnics.com
PRESSURE SENSOR CHARACTERISTICS
MAXIMUM RATINGS
Supply Voltage VS +18 VDC
Common-mode Pressure 150 In. H2O
Lead Temperature (Soldering, 4 seconds) 250癈
Proof Pressure 10 In. H2O
Burst Pressure 5 psi
ENVIRONMENTAL SPECIFICATIONS
Temperature Range
Compensated 0 to 50癈
Operating 0癈 to 70癈
Storage 0癈 to 70癈
Humidity Limits 0 to 80 %RH
WARNING:
Due to the delicate nature of these very
sensitive devices, some special handling is
required. Parts are sensitive to shock and
vibration and must be handled with care.
Dropping on any hard surface (bench top etc.)
can destroy the device. Note 10 In. H2O max.
overpressure.
SCXL004 PERFORMANCE CHARACTERISTICS
Characteristic
Operating Pressure Range
Sensitivity
Full-scale Span2
Zero Pressure Offset
Combined Linearity and Hysteresis3
Temperature Effect on Span (0-50癈)4
Temperature Effect on Offset (0-50癈)4
Repeatability5
Input Impedance6
Output Impedance7
Common-mode Voltage8
Response Time9
Long Term Stability of Offset and Span10
Position Sensitivity
Proof Pressure11
Min.
---
---
38
-1.5
---
---
---
---
---
---
5.7
---
---
---
---
Typ.
---
10
40
0
?.5
?.5
?.50
?.2
4.0
4.0
6.0
500
?.5
0.25
10
Max.
4
---
42
1.5
?.0
?.0
?.5
---
---
---
6.3
---
---
---
---
Unit
In. H2O
mV/In. H2O
mV
mV
%FS
%FS
mV
%FS
kW
kW
VDC
靤
%FS
mV/g
In. H2O
SPECIFICATION NOTES:
1. Reference conditions: Unless otherwise noted: Supply voltage, VS = 12 V, TA = 25癈, Common-mode Line Pressure = 0 psig, Pressure Applied to Port B.
2. Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Span is ratiometric to the supply voltage.
3. Zero pressure effect is measured with pins pointed towards the ground. Offset can be position sensitive.
4. Maximum error band of the offset voltage and the error band of the span, relative to the 25癈 reading.
5. Maximum difference in output at any pressure with the operating pressure range and temperature within 0癈 to +50癈 after:
a) 100 temperature cycles, 0癈 to 50癈
b) 1.0 million pressure cycles, 0 psi to full-scale span
6. Input impedance is the impedance between pins 2 and 4.
7. Output impedance is the impedance between pins 3 and 5.
8. This is the common-mode voltage of the output arms (Pins 3 and 5) for VS = 12 V.
9. Response time for a 0 psi to full-scale span pressure step change, 10% to 90% rise time.
10. Long term stability over a one year period.
11. Proof pressure is the pressure above which devices will not return to guaranteed specifications.
SCXL004DN
Precision Compensated, Low Pressure Sensors
January 1998/043
Aubinger Weg 27, 82178 Puchheim, Germany
Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33
http://www.sensortechnics.com
PHYSICAL DIMENSIONS
Mass: 5 grams Dimensions in inches (mm)
ORDERING INFORMATION
To order, use the following part number.
Description
0 to 4 In. WC
Part Number
SCXL004DN
WARNING:
Due to the delicate nature of these very sensitive devices, some special handling is required. Parts are sensitive to
shock and vibration and must be handled with care. Dropping on any hard surface (bench top etc.) can destroy the
device. Note 10 In. H2O max. overpressure.
SenSym and Sensortechnics reserve the right to make changes to any products herein. SenSym and Sensortechnics do not assume any liability arising out of the application or use of any product
or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
- 山东淄博飞雁先行测控技术有限公司 [加为商友]
- 联系人王月波(先生) 市场销售
- 地区山东-淄博市
- 地址张店区一帆路科汇工业园