- 产品品牌:美国,泰克
- 产品型号:TCP0150
本公司供应TCP0150电流探头质量保证,欢迎咨询洽谈。
Characteristic | Description |
|---|---|
Bandwidth | DC to ≥20 MHz (-3 dB). Derate with Frequency. See Figure 1. (Calculated from Rise Time BW = .35/Rise Time) |
Rise Time | ≤17.5 ns |
Max RMS Current | 150 A |
Max Peak Pulse Current | 500 A |
Minimum Sensitivity | 5 mA (on oscilloscope’s 1 mV/div setting) AC Coupling (on oscilloscopes that support AC/DC coupling) |
Current Ranges | 25 A and 150 A |
Max Bare-wire Voltage | 600 VRMS CAT I and II 300 VRMS CAT III |
Typical
Characteristic | Description |
|---|---|
DC Accuracy | ±1% Typical 3% Warranted |
Max Amp-second Product | |
25 A Range | 3,000 Aµs |
150 A Range | 15,000 Aµs |
Insertion Impedance | 0.03 Ω at 1 MHz |
0.075 Ω at 5 MHz | |
.125 at 10 MHz | |
.3 at 20 MHz | |
Signal Delay | 21 ns |
Displayed RMS Noise | ≤500 μARMS (probe only) |
Environmental
Characteristic | Description |
|---|---|
Temperature | |
Operating | 0 ºC to +50 ºC |
Nonoperating | -40 ºC to +75 ºC |
Humidity | |
Operating | 5% to 95% RH (Relative Humidity) at up to +30 ºC 5% to 85% RH above 30 ºC up to +50 ºC, noncondensing |
Nonoperating | 5% to 95% RH (Relative Humidity) at up to +30 ºC 5% to 85% RH above 30 ºC up to +75 ºC, noncondensing |
Altitude | |
Operating | Up to 2,000 meters (6,560 feet) |
Nonoperating | Up to 12,000 meters (40,000 feet) |
Physical Characteristics
Dimension | Meters | Inches |
|---|---|---|
Cable Length | 2 meters | 79 in. |
Probe head size | ||
Length | 26.8 cm | 10.55 in. |
Width | 4.1 cm | 1.6 in. |
Height | 15.6 cm | 6.13 in. |
Max Conductor Diameter | 21 mm x 25 mm | 0.83 in. x 1.0 in. |
Weight | kg | lb. |
Shipping | .7865 | 1.734 |
Power Requirements | TCP0150 is powered directly by the DPO4000, MSO4000 and DPO7000 Series oscilloscopes using TekVPI interface | |
Recommended Oscilloscopes
DPO4000, MSO4000, and DPO7000 Series oscilloscopes with TekVPI probe interface.
Note: Requires DPO7000 Series Firmware Version 3.0.2 or greater. Requires MSO/DPO4000 Firmware Version 2.06 or greater.
Figure 1.
Figure 2.
Figure 3: Do not apply currents greater than the max continuous current for more than 10 seconds to minimize heating effects.