- 产品品牌:V1060
- 产品型号:V1060
爆!V1060 回收二手V1060 收购V1060 模拟示波器
爆!V1060 回收二手V1060 收购V1060 模拟示波器
深圳市力博尔电子科技有限公司
联系人:李生;
电话:0755-61580367
手机:13528825696
QQ: 1731603260
电子邮箱:w88w889@163.com
地址:深圳市罗湖区蔡屋围京基金融中心蔡屋围金龙大厦1618
本公司长期高价收购/回收:Agilent、HP、Anritsu、Advantest、R/S、/MARCONI网络分析仪、手机综合测试仪、无线电综合测试仪、万用表校准仪、频谱分析仪、视频分析仪、音频分析仪、噪声系数分析仪、蓝牙测试仪、视频图象信号源、LCR测试仪(电桥)、高低频信号源、示波器、万用表、手机程控电源、电子负载、频率计、功率计、仪器配件,GPIB卡、GPIB转USB线等等。欢迎来电咨询!!! 李生:13528825696
商品简介:
V1060:日本日立,双踪双扫100M,X轴自动设定,CRT数字显示,
Y轴灵敏度:2mv/div-5v/div.
X轴扫速:50ns-0.5s/div,有X10扩展,示波管为15cm方屏内刻度。
外形尺寸:280X130X350mm,
重约:5.5kg ,220v/35w
The Hitachi portable read-out oscilloscope provides measure-ment reliability and ease of operation by employing amicroprocessor.
The major features are:
(1) Measurement information display
The measurement information including the sweep speed, thedelay time, the IJNCAL display, and the voltage sensitivity ofthe vertical axis (V-1065 ,V-1065C and V-665 only) is alpha-numerically displayed on the CRT.
Since troublesome setting operation procedures are eliminat-ed, an operator can concentrate on the displayed data formeasurement.
(2) Measurement value display (V-1065, V-1065C, V-665 only)
The distance between the two cursors displayed can read out the following;
△V : Voltage between the reference cursor and the deltacursor
△T : Time between the reference cursor and the deltacursor
1/△T: Reciprocal of the time
The displayed data eliminates troublesome and time consumingcalculation procedures. Moreover, miscalculation of thescales is completely avoided.
(3) Automatic time base range setting
At a press of the AUTO button, an optimum time base range is automatically set.(A signal period from 1.6 to 4 cyclesapprox. is displayed.)The time base range is automatically changed to a correspond-ing change in input signal period.
(4) Trigger lock
Since complicated pulse train waveforms are hard to trigger on, performing the trigger lock function enables sweep independent triggering. The "sweep time plus holdoff time"is fixed and a stable trigger is obtained at any time range.
(5) Bandwidth
V-1065,V-1065C,: DC-100 MHz from 5 V/div to S mv/div
V-1060 DC-20 MHz at 2 mV/div
V-665, V-660 : DC-60 MHz from 5 V/div to S mv/div
(6) High sensitivity
DC-10 MHz at 2 mv/divHigh sensitivity of 2 mV/div is provided.
(7) Internal graticule
Internal graticule lines eliminate parallax-viewing errorbetween the trace and the graticule lines.
(8) Delayed sweep
With delayed sweep, a portion of the signal can be magnifined for more accurate measurement and the windows of delayed sweep(B) is indicated on the main sweep(A) with cursors.
(9)Auto trigger level
Auto measuring of trigger level is employed, so that trigger level range is mathed to the trigger signal for maximum trigger sensitivity and stability.
(10)TV triggering
Exclusive TV sync separator circuit technology provides stable TV signal measurements on fields, frames and lines.
Specifications
(A) Frequency counter
1.1 Specifications
Measuring signal : Measure the signal selected as atrigger signal by the TRIG SOURCEOR X switch.
Measuring range : 20 Hz to 100 MHz
Accuracy of reference signal : 100 ppM (15 to 35°C)
Measuring range Display format Resolution Accuracy
20Hz≤f<100Hz 99.99Hz 0.01Hz Ref.signal ±1 LSD
100Hz≤f<1kHz 999.9Hz 1.0Hz Max
1kHz≤f<10kHz 9.999Hz 0.002Hz Max
10kHz≤f<100kHz 99.99Hz 0.04Hz Max
100kHz≤f<1MHz 999.9Hz 0.1Hz
1MHz≤f<10MHz 9.999Hz 0.002Hz Max
10MHz≤f<100MHz 99.99Hz 0.01Hz
100MHz≤f (999.9Hz) Not specified
1 .2 Frequency measurement
- 深圳市力博尔电子科技有限公司 [加为商友]

- 联系人程琼(先生)
- 地区广东-深圳市
- 地址深圳市福田区华民路85号












