发布信息当前位置: 首页 » 供应 » 电子/通信测量 » 示波器 » 供应V1060 模拟示波器 程琼:13556833108

供应V1060 模拟示波器 程琼:13556833108

点击图片查看原图
公司: 深圳多隆电子仪器有限公司 
型 号: V1060 
单 价: 面议 询价 
最小起订量:    
供货总量:
发货期限: 自买家付款之日起 1 天内发货
有效期至: 长期有效
最后更新: 2012-07-05
相关信息
 
产品详细说明
产品型号:V1060

!!出售V1060 模拟示波器 程琼:13556833108

深圳多隆电子仪器有限公司
程生:13556833108
QQ: 971090887
E-mail:chengqiong8@163.com                            
MSN:chengqiong8@msn.cn
电话:0755-61580256
传真:0755-61580525
地址:深圳市福田区华民路126号

商品简介:
V1060:日本日立,双踪双扫100M,X轴自动设定,CRT数字显示,
Y轴灵敏度:2mv/div-5v/div.
X轴扫速:50ns-0.5s/div,有X10扩展,示波管为15cm方屏内刻度。
外形尺寸:280X130X350mm,
重约:5.5kg ,220v/35w 
The Hitachi portable read-out oscilloscope provides measure-ment reliability and ease of operation by employing amicroprocessor.
The major features are:

(1) Measurement information display

The measurement information including the sweep speed, thedelay time, the IJNCAL display, and the voltage sensitivity ofthe vertical axis (V-1065 ,V-1065C and V-665 only) is alpha-numerically displayed on the CRT.

Since troublesome setting operation procedures are eliminat-ed, an operator can concentrate on the displayed data formeasurement.

(2) Measurement value display (V-1065, V-1065C, V-665 only)

The distance between the two cursors displayed can read out the following;

△V : Voltage between the reference cursor and the deltacursor
△T : Time between the reference cursor and the deltacursor
1/△T: Reciprocal of the time

The displayed data eliminates troublesome and time consumingcalculation procedures. Moreover, miscalculation of thescales is completely avoided.

(3) Automatic time base range setting

At a press of the AUTO button, an optimum time base range is automatically set.(A signal period from 1.6 to 4 cyclesapprox. is displayed.)The time base range is automatically changed to a correspond-ing change in input signal period.

(4) Trigger lock

Since complicated pulse train waveforms are hard to trigger on, performing the trigger lock function enables sweep independent triggering. The "sweep time plus holdoff time"is fixed and a stable trigger is obtained at any time range.

(5) Bandwidth

V-1065,V-1065C,: DC-100 MHz from 5 V/div to S mv/div
V-1060  DC-20 MHz at 2 mV/div
V-665, V-660 : DC-60 MHz from 5 V/div to S mv/div

(6) High sensitivity

DC-10 MHz at 2 mv/divHigh sensitivity of 2 mV/div is provided.

(7) Internal graticule

Internal graticule lines eliminate parallax-viewing errorbetween the trace and the graticule lines.

(8) Delayed sweep

With delayed sweep, a portion of the signal can be magnifined for more accurate measurement and the windows of delayed sweep(B) is indicated on the main sweep(A) with cursors.

(9)Auto trigger level

Auto measuring of trigger level is employed, so that trigger level range is mathed to the trigger signal for maximum trigger sensitivity and stability.

(10)TV triggering

Exclusive TV sync separator circuit technology provides stable TV signal measurements on fields, frames and lines.

 

Specifications

(A) Frequency counter

1.1 Specifications

Measuring signal : Measure the signal selected as atrigger signal by the TRIG SOURCEOR X switch.
Measuring range : 20 Hz to 100 MHz
Accuracy of reference signal : 100 ppM (15 to 35°C)

 

Measuring range Display format Resolution Accuracy
20Hz≤f<100Hz 99.99Hz 0.01Hz Ref.signal ±1 LSD
100Hz≤f<1kHz 999.9Hz 1.0Hz Max
1kHz≤f<10kHz 9.999Hz 0.002Hz Max
10kHz≤f<100kHz 99.99Hz 0.04Hz Max
100kHz≤f<1MHz 999.9Hz 0.1Hz
1MHz≤f<10MHz 9.999Hz 0.002Hz Max
10MHz≤f<100MHz 99.99Hz 0.01Hz
100MHz≤f (999.9Hz) Not specified

1 .2 Frequency measurement


 


公司联系方式
同类产品

[ 供应搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

中国测控网郑重提醒:网上过低的价格有可能是虛假价格信息,请买家谨慎对待,谨防价格欺诈行为。投诉或价格欺诈行为,请发送邮件至 1365099215@qq.com