| 品牌: | Labsphere | 型号: | CDS-600 | 光源: | LED |
| 波长范围: | 200-850(nm) | 焦距: | 光纤(mm) | 外形尺寸: | 89.1 mm x 63.3 mm x 34.4 mm(mm) |
| 重量: | 190 grams(g) | 适用范围: | Light Measurement Spheres |
CDS-600 小型CCD阵列光纤光谱仪

产品特点:
宽的光谱测量范围(200-800nm)完善的光测量软件2 nm 光谱分辨率波长精度<0.5 nm快速的CCD阵列探测器3 m 光纤最佳应用范围:
The highly sensitive CDS 600 and CDS 610 Mini CCD Array Spectrometers offer low noise and a broad spectral response with calibrated ranges from 200 to 850 nm or 350 to 1000 nm. When coupled with a Labsphere integrating sphere, the spectrometers avoid the inherent photometric errors associated with filter-based photometers. Data is accurate even for narrow-band light sources such as LEDs, fluorescent lamps, and discharge lamps. In production, these systems can increase the throughput of quality assurance testing, which facilitates improved statistical process control for higher manufacturing consistency and greater product quality.
The Labsphere CDS CCD Array Spectrometers are multi-channeled spectral analyzers designed for real-time spectral analysis. Instantaneous spectral acquisition provides the radiometric, photometric, and color characteristics of the device under test (DUT). Fast results help to increase the rate of product development, decrease the time to market, and reduce development costs.
The CDS CCD Array Spectrometers easily connect to a PC via an USB-2 port and use a fiber optic cable to connect to the optical head, enabling the remote positioning of the spectrometer. The Windows® XP-based software guides the user through testing procedures making complex spectral measurements simple while still meeting the needs of experienced researchers。
System Includes
Labsphere’s CDS CCD Array Spectrometer3 meter Fiber Optic Input2 meter USB-2 CableRequired, Sold Separately:MtrX-SPEC Spectral Light Measurement Software
The CDS CCD Array Spectrometers are designed for use with Labsphere’s LED, flashlight, and light measurement spheres and optical heads. To calibrate for light measurement, reference standards of total spectral flux are available for system calibration. For a comprehensive spectral light measurement solution, reference Labsphere’s complete line of Spectral Light Measurement Systems.
PRODUCT PROPERTIES AND PERFORMANCE
| MODEL | CDS 600 | CDS 610 |
| Wavelength Range: | 200-850 nm | 350-1000 nm |
| Signal-to-Noise Ratio: | 250:1 (at full signal) | 250:1 (at full signal) |
| A/D Resolution: | 16 bit | 16 bit |
| Dark Noise: (correctable) | 50 RMS counts | 50 RMS counts |
| Dynamic Range: | 2 x 10^8 (system); | 2 x 10^8 (system); |
| Dynamic Range for Single Acquisition: | 1300:1 | 1300:1 |
| Integration Time: | 8 ms to 30 seconds | 8 ms to 30 seconds |
| Stray Light: | <0.05% at 600 nm; <0.10% at 435 nm | <0.05% 600 nm; <0.10% at 435 nm |
| Corrected Linearity: | >99.8% | >99.8% |
Electronics | ||
| Power Consumption: | 90 mA @ 5 VDC | 90 mA @ 5 VDC |
| Connector: | 10-pin connector | 10-pin connector |
Computer | ||
| Operating Systems: | Windows XP with USB port | Windows XP with USB port |
| Computer Interfaces: | USB 2.0 @ 480 Mbps | USB 2.0 @ 480 Mbps |
| Dimensions: | 89.1mmx63.3mmx34.4mm | 89.1mmx63.3mmx34.4mm |
| Weight: | 190 grams | 190 grams |
Detector: | ||
| Detector: (Silicon CCD array) | Sony ILX511 linear | Sony ILX511 linear |
| Detector Range: | 200-1100 nm | 350-1000 nm |
| Pixels: | 2048 pixels | 2048 pixels |
| Pixel Size: | 14 μm x 200 μm | 14 μm x 200 μm |
| Pixel Well Depth: | ~62,500 electrons | ~62,500 electrons |
| Sensitivity: | 75 photons/count at 400 nm; 41 photons/count at 600 nm | 75 photons/count at 400 nm; 41 photons/count at 600 nm |
Optical Bench | ||
| Design: | f/4, Symmetrical crossed Czerny-Turner | f/4, Symmetrical crossed Czerny-Turner |
| Focal Length: | 42 mm input; 68 mm output | 42 mm input; 68 mm output |
| Entrance Aperture: | 100 µm | 100 µm |
| Fiber Optic Connector: | SMA 905 to 0.22 numerical aperture single-strand optical fiber | SMA 905 to 0.22 numerical aperture single-strand optical fiber |
Compatible With:
LMS Light Measurement Spheres
I 1000 Spectral Intensity Head
I 2000 Spectral Intensity Head
E 1000 Spectral Irradiance Receiver