PXR系列温控器简介:
◆双排显示PV、SV等数据;
◆多种热电偶信号、热电阻信号、线形信号输入;
◆带手/自动模式,切换便利;
◆ 8段斜坡/保温程序(选件)
◆满量程0.5%精度,85-256V AC 50/60HZ供电工作。
◆ 再传输输出功能DC4-20ma和RS485通讯功能(选件)
◆遥控输入功能(选件)
富士温控表PXR4/5/7/9系列选型说明
数字位
|
规格
面板尺寸W×H
|
代号
|
||||||||||
4
|
5
|
6
|
7
|
8
|
-
|
9
|
10
|
11
|
12
|
13
|
||
4
|
48×48mm
|
4
|
|
|
|
|
|
|
|
|
|
|
48×96mm
|
5
|
|
|
|
|
|
|
|
|
|
|
|
72×72mm
|
7
|
|
|
|
|
|
|
|
|
|
|
|
96×96mm
|
9
|
|
|
|
|
|
|
|
|
|
|
|
5
|
输入信号
|
|
|
|
|
|
|
|
|
|
|
|
热电偶(℃)
|
|
T |
|
|
|
|
|
|
|
|
|
|
热电偶(℉)
|
|
R |
|
|
|
|
|
|
|
|
|
|
RTD/Pt100欧姆(℃)
|
|
N
|
|
|
|
|
|
|
|
|
|
|
RTD/Pt100欧姆(℉。)
|
|
S
|
|
|
|
|
|
|
|
|
|
|
1~5V DC
|
|
A
|
|
|
|
|
|
|
|
|
|
|
4~20mA DC
|
|
B
|
|
|
|
|
|
|
|
|
|
|
6
|
控制输出1
|
|
|
|
|
|
|
|
|
|
|
|
继电器接点输出
|
|
|
A |
|
|
|
|
|
|
|
|
|
SSR/SSC驱动输出
|
|
|
C |
|
|
|
|
|
|
|
|
|
4~20mA DC输出 注1
|
|
|
E
|
|
|
|
|
|
|
|
|
|
7
|
控制输出2
|
|
|
|
|
|
|
|
|
|
|
|
无
|
|
|
|
Y |
|
|
|
|
|
|
|
|
继电器接点输出
|
|
|
|
A |
|
|
|
|
|
|
|
|
SSR/SSC驱动输出
|
|
|
|
C
|
|
|
|
|
|
|
|
|
4~20mA DC输出
|
|
|
|
E
|
|
|
|
|
|
|
|
|
再传输输出(4~20mA DC)
|
|
|
|
R
|
|
|
|
|
|
|
|
|
8
|
版本号
|
|
|
|
|
1
|
-
|
|
|
|
|
|
9.
|
附加功能1
|
|
|
|
|
|
|
|
|
|
|
|
无报警
|
|
|
|
|
|
|
0
|
|
|
|
|
|
1个报警
|
|
|
|
|
|
|
8
|
|
|
|
|
|
加热器断路报警 注2
|
|
|
|
|
|
|
2
|
|
|
|
|
|
1个报警+加热器断路报警 注2
|
|
|
|
|
|
|
3
|
|
|
|
|
|
8段斜坡/保温程序
|
|
|
|
|
|
|
4
|
|
|
|
|
|
1个报警+8段斜坡/保温程序
|
|
|
|
|
|
|
5
|
|
|
|
|
|
加热器断路报警+8段斜坡/保温程序 注2
|
|
|
|
|
|
|
6
|
|
|
|
|
|
1个报警+加热断路报警+8段斜坡/保温程序 注2
|
|
|
|
|
|
|
7
|
|
|
|
|
|
两个报警
|
|
|
|
|
|
|
F
|
|
|
|
|
|
两个报警+8段斜坡/保温
|
|
|
|
|
|
|
G
|
|
|
|
|
|
两个报警+加热器断路报警+8段斜坡/保温 注2
|
|
|
|
|
|
|
H
|
|
|
|
|
|
3个报警
|
|
|
|
|
|
|
M
|
|
|
|
|
|
遥控设定 注2
|
|
|
|
|
|
|
D
|
|
|
|
|
|
遥控设定+2个报警 注2
|
|
|
|
|
|
|
P
|
|
|
|
|
|
10
|
操作说明书 电源电压
|
|
|
|
|
|
|
|
|
|
|
|
中文 100~240VAC
|
|
|
|
|
|
|
|
W
|
|
|
|
|
日文 100~240VAC
|
|
|
|
|
|
|
|
Y
|
|
|
|
|
英文 100~240VAC
|
|
|
|
|
|
|
|
V
|
|
|
|
|
无 24VAC/24DC
|
|
|
|
|
|
|
|
C
|
|
|
|
|
日文 24VAC/24DC
|
|
|
|
|
|
|
|
A
|
|
|
|
|
英文 24VAC/24DC
|
|
|
|
|
|
|
|
B
|
|
|
|
|
11
12
13
|
附加功能2
|
|
|
|
|
|
|
|
|
|
|
|
无
|
|
|
|
|
|
|
|
|
0
|
0
|
0
|
|
RS485(Modbus)通讯
|
|
|
|
|
|
|
|
|
M
|
0
|
0
|
|
RS485(Z-ASC11) 通讯
|
|
|
|
|
|
|
|
|
N
|
0
|
0
|
|
1点数字输入
|
|
|
|
|
|
|
|
|
S
|
0
|
0
|
|
2点数字输入 注3
|
|
|
|
|
|
|
|
|
T
|
0
|
0
|
|
RS485(Modbus) 通讯+1点数字输入
|
|
|
|
|
|
|
|
|
V
|
0
|
0
|
|
RS485(Z-ASC11) 通讯+1点数字输入
|
|
|
|
|
|
|
|
|
W
|
0
|
0
|
|
注1:输出4-20mA不能与加热器断路报警一起选。(即选项9中的2、3、6、7、H)
|
||||||||||||
注3:若选择2点数字输入,输出2或加热器断路报警不能选。
|
||||||||||||
注2:不能与RS485+1点数字输入一起选。(即选项11、12、13中的V00)
|
公司联系方式
- 苏州迅鹏仪器仪表有限公司进口仪表事业部 [加为商友]
- 联系人屈小姐(女士) 市场销售
- 地区江苏-苏州市
- 地址桐泾北路26-6号