盐份测试工具包
◆ 测量范围:0.0-99.9ppm,100-999ppm
◆ 分辨率:0.1uS/cm,1uS/cm
◆ 精确度:±2%
◆ 有自动温度补偿
BRESLE-KIT Chloride test kit
Article number :SP7310
User-friendly test-kit for assessing the presence and level or soluble salts on blast-cleaned surfaces prior to coating. This unique method conforms to ISO8502-6 and 9 standards displays the results in milligram per square meter.
The test-kit consists or a digital conductivity meter, 20 Bresle Samplers, disposable cUPS and all other accessories.
The kit also contains the equipment to determine the contamination or the blast-media in use.
BRESLE KIT
A comPACt and user-friendly kit for asessment of the level of soluble salts on steel surfaces after pre-treatment.
· Assessment of soluble salts before applying a coating is essential.
· An absolute clean surface is a must for succesful coating work.
· With the TQC Bresle-kit the presence of soluble salts, expressed in milligram per square meter, can easily be determined.
· Check your specifications for the acceptable salt levels !
· The metho
is simple, accurate and according to international standards:
o ISO8502-9
"Field method for soluble salts
by conductometric measurement"
o ISO8502-6
"Extraction of soluble contaminants
for analysis-The Bresle method"
· The kit also contains the equipment to determine the contamination of the blast-media in use.
Salt trapped under a coating layer will attract moisture due to its hygroscopic nature. Corrosion and pitting will occur rapidly.
|
|
|
|
|
|
Moisture | |
|
|
Coating | |
|
|
Salt | |
|
|
Substrate |
Check your specifications for the acceptable salt levels
|
|
|
Note the test-results |
| ||||
|
|
|
|
|
|
|
|
|
|
Take 15 ml. test liquid and pour in the disposable beaker. |
|
Determine the conductivity of the test-liquid. |
|
Apply the Bresle patch on the surface to be measured. |
|
Inject the test-liquid in the sampler to solve the present salts in the liquid. |
Take out the liquidand determine the conductivity again |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The difference between the conductivity in step 2 and 5 multiplied by 6 is the quantity of soluble salts in Milligrams per Square meter. |
- 广州市盛华化工科技有限公司 [加为商友]
- 联系人曾活勇(先生) 市场销售
- 地区广东-广州市
- 地址黄浦区黄埔东路5好东城广场1818