The Cadex C8000 battery testing system is equipped with digital drivers to handle batteries from 50mAh to 100Ah. Put performance in your hands with cell monitoring, safety circuit checks and SMBus battery testing. Capture load
signatures from power tools, laptops, etc. and use the simulated loads to check battery runtime. Add accessories such as thermal chambers and external load banks and you begin to realize the Cadex C8000 stands in a class by itself.
One of the most desirable qualities of the Cadex C8000 is flexibility and ease of use. The system offers a broad testing range and also services fuel cells and solar cells.
Nominal voltage range 1.2V to 36V
Current up to 10A charge & discharge
Tests batteries from 50mAh to 100Ah
Cadex C8000 Controller
Independent channels 4 separate Battery Ports and I/O Ports.
System Desktop or 19” rack mount. Portable version on request. Comes with PC-
BatteryLab(TM) software. System can be used in stand-alone mode or with PC.
Battery voltage range 1.2 to 36V nominal; settable in 1mV increments
1 to 10 serial connection of lithium-ion cells (3.6V/cell)
1 to 18 serial connection of lead acid cells (2.0V/cell)
1 to 25 serial connection of nickel-based cells (1.20V/cell)
Battery test range 50mAh to 100Ah typical. External charger and load bank for larger batteries.
Charge/discharge current 10mA to 10A, settable in 1mA increments.
Maximum charge power 100W per station; 400W total. Each station can charge at 100W continuously.
Maximum discharge power 80W per station; 320W total. Each station can discharge at 80W simultaneously.
Power management Current automatically scales down if power demand is above 80W on discharge or 100W on charge; message indicates scaled service.
Line voltages 90 to 264VAC, 50-60Hz; max 1200W loading on main.
Battery chemistries Lithium-ion, nickel-metal-hydride, nickel-cadmium, lead-acid. Parameters are changeable; custom charge algorithms possible for specialty chemistry.
Battery interface Power Port Supplied 4 Power Cables, 1.8 m (6’), with banana terminals and alligator clips;
4-wire system; detachable temperature sensor. Maximum current 10A.
I/O Port Supplied 4 DB25 cables, 1.8 m (6’), open-ended.
Battery Adapters SnapLock(TM) Battery Adapters interface with optional SnapLock Adapter Unit.
The Battery Adapter stores up to 10 battery-specific C-CODes that configure the analyzer to the correct setting. Maximum current 6A.
Charge method Lithium-ion and lead-acid: Constant voltage with current limit.
Nickel-based: Constant current with optional Reverse Load Charge method,
adjustable from 5-12%. Automatic full charge detection.
Manual settings possible on Custom Program.
Discharge method Can be set to constant current or constant power discharge with PC-BatteryLab(TM).
Discharges to set voltage threshold. Manual settings possible on Custom Program.
Battery service programs Grouped into Basic, Advanced, Rapid-Test, Custom and Manual. Jump command
advances to the next cycle or retracts to the previous setting.
Basic Charge, Auto, Prime.
Advanced Load Test, Runtime, Lifecycle, Self-discharge, Discharge Only, Extended Prime.
Rapid-Test QuickSort(TM)* (500-1500mAh Li-Ion), QuickTest(TM)*, Learn* (to create QuickTest(TM)
matrices), OhmTest(TM), AC Impedance.
Custom Allows creating and storing 100 customized programs consisting of up to 100 steps
per program. Programmable by BatteryLab(TM). The programming decisions are based
on voltage thresholds, delta-V, current levels, delta-I, temperature, delta-T, time,
number of cycles, open circuit, AC impedance, DC resistance, SMBus flags and
other threshold parameter.
Specialty Enables advanced load and circuit testing*
(via PC only) Load Signature Acquisition: Tests power source with captured load signature.
Charger Function Test: Examines charger functions.
Battery Safety Circuit Test: Verifies operation of batteries with safety devices
Security Password protection prevents unauthorized access.
Display 5.7” diagonal QVGA resolution (320x240) graphics display with backlight
Power failure recovery Retains the test data on power failure and resumes when power is restored. The time
stamp on power failure and resumption is recorded.
Accuracy +/-0.1% on voltage; +/-0.25% on current; full scale.
Sample rate 10 milliseconds, display updated every 1 second; data logging 1 – 60 seconds.
Battery Ports (4, Front Panel) Battery positive (+); Battery negative (-); Sense positive (+); Sense negative (-);
Thermistor input; Thermistor ground (-).
I/O Port (DB25, 4, Front Panel) 4 analog input, 0-5V, 12-bit resolution, floating ground, 0-50V common mode range.
4 on/off 5V TTL levels with open-drain output and 20mA (max) sinking ability.
2 general-purpose analog 0 – 3.3V I/P. SMBus, clock, data and ground.
Data Ports (Back) 1 only RS-232; 1 only Ethernet 10/100 for PC connection, included
Physical Width: 480mm (18.900”); Depth: 380 mm (15”); Height: 140 mm (5.51”) 3U
Weight 10 kg (22lb)
Environmental Recommended operating temperature 41F to 95 F; (5C to 35C)
Recommended storage temperatures -20C to 70C (-4F to 159F)
Firmware Upgradeable with BatteryLab(TM) (Included with system).
Approvals CSA 22.2 No: 61010-1, UL 61010-1 and EN61010-1; RoHS and WEEE compliant;
CE marked.
Warranty Cadex warrants the analyzer against defective materials and workmanship for a
period of two (2) years from the original purchase date.
*Scheduled for 2Q09
PC-BatteryLab(TM) Software (included)
Expandability BatteryLab(TM) is designed to accommodate 1 to 8 analyzers to service 32 batteries
independently (on most PCs).
Computer requirements: Dedicated PC with MS Windows XP Professional SP2; Ethernet connector; RS232
(Serial) Port; recommended 1.2 GHz CPU or better; 512 MB of RAM main memory
and at least 10 GB free hard disk sPACe. HD free space requirements increases in
line with the amount of data retained.
Recommended peripherals TBD.
- 北京恒达世佳科技有限公司 [加为商友]

- 联系人张宁(先生) 销售经理
- 地区北京
- 地址北京市朝阳区北苑路天月3幢1-101室