管道内无可动部件,无阻流部件,测量中几乎没有附加压力损失。
测量结果与流速分布、流体压力、温度、密度、粘度等物理参数无关。
电极材质防腐选用参考表 |
介质名称
|
浓度%
|
温度
|
316L
|
哈氏C℃
|
钛
|
钽
|
铂
|
甲酸
|
10-50
|
室温
|
N
|
A
|
A
|
A
|
A
|
沸点
|
N
|
B
|
A
|
A
|
A
|
50-100
|
室温
|
N
|
B
|
B
|
A
|
A
|
沸点
|
N
|
N
|
N
|
A
|
A
|
草酸
|
5-10
|
室温
|
A
|
A
|
A
|
X
|
A
|
25-50
|
室温
|
|
A
|
A
|
X
|
A
|
Sat
|
室温
|
|
N
|
B
|
X
|
A
|
5-Sat
|
沸点
|
N
|
N
|
N
|
X
|
A
|
柠檬酸
|
5-25
|
室温
|
A
|
A
|
A
|
X
|
A
|
沸点
|
A
|
A
|
A
|
X
|
A
|
50
|
室温
|
A
|
A
|
A
|
X
|
A
|
沸点
|
A
|
A
|
B
|
X
|
A
|
氯化铁
|
10-Sat
|
室温
|
N
|
A
|
A
|
A
|
|
沸点
|
N
|
A
|
A
|
A
|
A
|
氯化钠
|
100
|
室温
|
B
|
A
|
A
|
X
|
A
|
沸点
|
B
|
A
|
A
|
X
|
A
|
氯化铵
|
10-20
|
室温
|
N
|
B
|
B
|
A
|
A
|
沸点
|
N
|
B
|
B
|
A
|
A
|
50-100
|
室温
|
N
|
B
|
B
|
X
|
A
|
沸点
|
N
|
B
|
B
|
X
|
A
|
氯化钙
|
100
|
室温
|
N
|
N
|
|
A
|
A
|
沸点
|
|
X
|
|
A
|
A
|
氯化镁
|
10-30
|
室温
|
N
|
B
|
B
|
A
|
A
|
沸点
|
N
|
B
|
|
X
|
A
|
硝酸钾
|
20-50
|
室温
|
A
|
A
|
A
|
X
|
A
|
沸点
|
A
|
A
|
A
|
X
|
A
|
80-Sat
|
室温
|
A
|
A
|
A
|
X
|
A
|
沸点
|
N
|
A
|
A
|
X
|
A
|
硫酸钠
|
Sat
|
室温
|
A
|
A
|
A
|
A
|
A
|
沸点
|
N
|
N
|
|
A
|
A
|
脂肪酸
|
100
|
室温
|
N
|
A
|
A
|
X
|
A
|
100
|
沸点
|
|
A
|
A
|
X
|
A
|
乳酸
|
1.5-10
|
室温
|
A
|
A
|
A
|
X
|
A
|
1.5-10
|
沸点
|
N
|
|
A
|
X
|
|
Sat
|
沸点
|
N
|
N
|
A
|
A
|
|
硝酸铝
|
10
|
室温
|
A
|
X
|
A
|
A
|
|
10-100
|
室温
|
|
X
|
A
|
X
|
A
|
57
|
120℃
|
|
X
|
A
|
X
|
|
纸浆
|
|
室温
|
B
|
A
|
A
|
A
|
A
|
石灰浆
|
|
室温
|
N
|
B
|
A
|
A
|
A
|
|
|
|
|
|
|
|
|
工作原理
法拉第感应定律(指的是当导体通过磁场是会在导体内部产生感应电势)即为电磁流量计测量的基础原理。这种测量原理可应用于具有导电性的流体,该流体流入磁场垂直于流体方向的管道,在流体中感应生成的电势可利用对称布置的两个电极进行测量。信号电压UE与磁感应强度B,电极间距D以及流体平均速度V成正比。由于磁感应强度B与电极间距D为常量,所以信号电压UE与平均流速V成正比。用于计算体积流速的等式表明信号电压UE与体积流量成线性正比。感应的信号电压被转化为转换器中的分度,模拟以及数字输出信号。
标准技术规格 |
1. 正常工作条件
环境温度:-25~+60℃;
相对湿度:5%~90%;
供电电源:单相交流电源85~250V,45~63HZ;直流电源16VDC~36VDC;
耗散功率:小于20W。
2. 测量精度
标准型SE11/卫生型SE13:±0.5% 高精度SE12:±0.25% 插入式SE14:±1.5%
|
3. 输出变量
3.1模拟电流输出
负载电阻:0~10mA时,0~1.5kΩ;
4~20mA时,0~750Ω。
基本误差:0.1%±10µA。
3.2数字频率输出
频率输出范围:1~5000HZ;
输出电气隔离:光电隔离,隔离电压:>1000VDC;
频率输出驱动:场效应管输出,最高承受电压36VDC,最大负载电流250mA。
3.3数字脉冲输出
输出脉冲范围:0~100脉冲/秒。(高于上限时,会丢失脉冲)
输出脉冲当量:0.001~1.000m3/cp;
0.001~1.000 LTR/CP;
0.001~1.000 USG/CP;
0.001~1.000 UKG/CP;
输出脉冲宽度:用户软件设置;
输出电气隔离:光电隔离,隔离电压:>1000VDC;
脉冲输出驱动:场效应管输出,最高承受电压36VDC,最大负载电流250mA。
3.4报警输出
报警输出接点:ALMH---上限报警;ALML---下限报警;
输出电气隔离:光电隔离,隔离电压:>1000VDC;
报警输出驱动:达林顿管输出,最高承受电压36VDC,最大负载电流250 mA。
3.5数字通讯接口及通讯协议
MODBUS接口:RTU格式,物理接口RS-485,电气隔离1000V;
MART接口:支持标准HART协议,配置HART375手持器,可在线显示测量值,并可修改仪表参数
流量计口径、公称压力和流量范围
瞬时体积流量是流速和传感器口径的函数。瞬时流量列线图表明每一口径流量计可以测量的流量范围,同时给出适合测量某给定流量的几种传感器口径规格。
口径
DN
|
压力
MPA
|
最小流量范围
流速0-0.5m/s
|
最大流量范围
流速0-10m/s
|
3
|
4.0
|
0-0.2L/min
|
0-4L/min
|
4
|
4.0
|
0-0.4L/min
|
0-8L/min
|
6
|
4.0
|
0-1.0L/min
|
0-20L/min
|
8
|
4.0
|
0-1.5L/min
|
0-30L/min
|
10
|
4.0
|
0-2.25L/min
|
0-45L/min
|
15
|
4.0
|
0-5L/min
|
0-100L/min
|
20
|
4.0
|
0-7.5L/min
|
0-150L/min
|
25
|
4.0
|
0-10L/min
|
0-200L/min
|
32
|
4.0
|
0-20L/min
|
0-400L/min
|
40
|
4.0
|
0-30L/min
|
0-600L/min
|
50
|
4.0
|
0-3m3/h
|
0-60m3/h
|
65
|
4.0
|
0-6m3/h
|
0-120m3/h
|
80
|
4.0
|
0-9m3/h
|
0-180m3/h
|
100
|
1.6
|
0-12m3/h
|
0-240m3/h
|
125
|
1.6
|
0-21m3/h
|
0-420m3/h
|
150
|
1.6
|
0-30m3/h
|
0-600m3/h
|
200
|
1.6
|
0-54m3/h
|
0-1080m3/h
|
250
|
1.6
|
0-90m3/h
|
0-1800m3/h
|
300
|
1.0
|
0-120m3/h
|
0-2400m3/h
|
350
|
1.0
|
0-165m3/h
|
0-3300m3/h
|
400
|
1.0
|
0-225m3/h
|
0-4500m3/h
|
500
|
1.0
|
0-330m3/h
|
0-6600m3/h
|
600
|
1.0
|
0-480m3/h
|
0-9600m3/h
|
700
|
1.0
|
0-660m3/h
|
0-13200m3/h
|
800
|
1.0
|
0-900m3/h
|
0-18000m3/h
|
900
|
1.0
|
0-1200m3/h
|
0-24000m3/h
|
1000
|
1.0
|
0-1350m3/h
|
0-27000m3/h
|
1200
|
0.6
|
0-2100m3/h
|
0-42000m3/h
|
1400
|
0.6
|
0-2700m3/h
|
0-54000m3/h
|
1600
|
0.6
|
0-3600m3/h
|
0-72000m3/h
|
1800
|
0.6
|
0-4500m3/h
|
0-90000m3/h
|
2000
|
0.6
|
0-5700m3/h
|
0-114000m3/h
|
电磁流量计的正确安装
1. 安装场所的选择:
■选择测量管内不会出现负压的场所;
■避免安装在电机、变压器强电设备附近,以免引起电气干扰;
■避免安装位置周围有强腐蚀性气体的场所;
■环境温度一般在-25℃~60 ℃范围内,尽可能避免阳光直射;
■安装在无振动或选择振动小的场合,如果振动过大,应该在传感器前后的管道上加固定支撑;
■环境相对湿度应该在5%-90%范围内;
■避免安装在能被雨水直淋或者浸没的场所;
2. 对直管段长度的要求:(D为流量计的内径)
电磁流量计对前后直管段的要求比较低,一般对于90 弯头,T形三通、异径管 、全开阀门等流动阻力件,离电磁流量计的电极轴中线(不是传感器的端面)应该有5D的直管段;对于不同开度的阀门(比如可调开度的阀门),则上游侧的直管段长度需要10D。一般传感器下游的直管段只需要3D就可以满足要求。
如图所示:
测量不同介质的混合液体时,混合点与流量计之间的距离至少要大于30D,如下图所示:
1. 安装位置和流动方向:
电磁流量计可以水平、 垂直和倾斜安装在管道上:
在水平安装时,电磁流量计的电机轴必须水平,防止由于流体所夹带的气泡而产生电极短时间的绝缘,也可以防止电极被流体中的沉积物覆盖。不应该将传感器安装在最高位置处,以免有气体积聚。
垂直安装时,应该使流动方向向上,这样可以使无流量或者流量很小时,流体中夹带的较重固体颗粒下沉,而轻的脂肪类物质上升离开电磁流量计的传感器电极区,在测量泥浆矿浆等液固两相介质时避免固相沉淀和传感器衬里不均匀摩擦。如图所示。
传感器的测量管道必须充满液体,必须有以一定的背压。为防止出现负压(损坏衬里),电磁流量计不应该安排在泵的进口,而应该安装在泵的出口;在倾斜安装时,必须安装在上升管道;在开口排放的管道安装时,必须安装在管道的较低处。
应在传感器的下游安装控制阀和切断阀,而不应该安装在传感器上游
现场管道上开取DN100通径的孔,再焊接通径DN100的管子和DN100PN1.6Mpa法兰。将标准型法兰固定插入式电磁流量计安装在法兰上。
在标准型法兰固定插入式电磁流量计安装在法兰的基础上,增加了全通DN100的球阀。用户可在不切断介质的情况下,将标准型在线插拔式电磁流量计抽至最高点,全比球阀,取出流量计
常见液体导电率参数表
介质名称
|
浓度%
|
温度℃
|
电导率(S/cm)
|
|
介质名称
|
浓度%
|
温度℃
|
电导率(S/cm)
|
硫酸
|
5
|
18
|
20.85*10-2
|
甲酸
|
4.94
|
18
|
55.00*10-4
|
85
|
|
98.50*10-3
|
39.955
|
|
98.40*10-4
|
99.4
|
|
85.00*10-4
|
100
|
|
2.80*10-4
|
盐酸
|
5
|
15
|
39.48*10-2
|
100(纯)
|
|
5.60*10-5
|
40
|
|
51.52*10-2
|
草酸
|
3.5
|
18
|
5.08*10-2
|
硝酸
|
6.2
|
18
|
31.23*10-2
|
5
|
18
|
67.20*10-3
|
31
|
|
79.19*10-2
|
氯化钠
|
10
|
|
12.11*10-2
|
62
|
|
49.04*10-2
|
26
|
|
21.51*10-2
|
氢氟酸
|
0.0004
|
18
|
2.50*10-2
|
氯化钙
|
5
|
|
6.43*10-2
|
0.121
|
|
21.00*10-2
|
25
|
|
17.81*10-2
|
4.80
|
|
59.3*10-3
|
35
|
|
13.66*10-2
|
29.80
|
|
34.11*10-2
|
氯化铵
|
5
|
18
|
91.80*10-3
|
醋酸
|
0.30
|
18
|
|