品牌:好辉牌红外线耳温枪 | 型号:KT103 | 类型:便携式 |
适用对象:人体测温仪 | 测量范围:10-80c° | 测量精度:±0.2℃ |
分辨率:0.1 | 尺寸:136*40mm(mm) | 重量:0.2(kg) |
加工定制:是 | 规格:136*40mm |
红外线耳温枪
KT103款耳温计是目前最先进一款耳温计,一机多用,可同时测耳温,额温,环温,水温。使用方便。
红外耳温枪是一种非接触式红外线温度测量仪器,它可以安全、快速地测量人体耳道内的温度,测量过程仅需1秒。适用于医院及家庭使用,特别适用于测量儿童体温。
技术参数:
测温范围:15.0℃~75.0℃(41.0℉~167.0℉)
当测量温度低于5.0℃时,显示L℃ ;
当测量温度高于75℃时,显示H℃。
使用环境条件:
温度:16℃~35℃(60.8℉~95℉)
湿度: ≦80%RH
运输贮存条件:
温度:-25℃~55℃(-13℉~131℉)
湿度:≦85%RH
分辨率:0.1℃
精度: (32℃~42.9℃) ±0.2℃ (from 95.9℉ to 107.6℉) ±0.4℃℉
显示方式:
液晶显示,4位数
温度值:显示测量过程中最大温度值
计量单位:摄氏度
记忆显示:显示最后10组测量温度值
低电压警告:液晶屏显示“ ”,同时发出蜂鸣提示
功耗:0.6毫瓦
电池:3v CR2032纽扣电池
电池寿命:2000次
彩盒尺寸:172*70*41mm
净重:约50克
蜂鸣信号:开/关, 测量结束和低电压警告等
外箱:外箱:44*36*23.5cm一箱60支
The ear thermometer is a device capable of achieving infra-red temperature measurement when placed in the auditory
cannal of a subject. It is a safe means of measuring human body temperature through the ear。
Specification:
The standard we adopted is EN12470-5:2003 Clinical thermometers—Part 5: Performance of infra-red
ear thermometers(with maximum device).
This device complies with the requirements of IEC60601-1:1998, and IEC60601-1-2:2001.
Range of displayed temperature:32℃~42.9℃(89.6℉~109.3℉)
Display L℃when the temperature is under 32℃
Display HI℃when the temperature is over 42.9℃。
Scan/M button |
Probe membrane |
Operating ambient:
Temperature:16℃~35℃(60.8℉~95℉) f
Humidity:≦80%RH
Storage and transport condition:
zTemperature:-25℃~55℃(-13℉~131℉)
ON/OFF button |
zHumidity:≦85%RH
Display resolution temperature range::0.1℃(0.2℉)
Accuracy:±0.2℃(from 35.5℃to 42℃)
±0.4℃℉(from 95.9℉to 107.6℉)
Probe cap |
DISPLAY:liquid crystal display, 3.5 digits
zTemperature value: display the maximum temperature
LCD |
In measuring process
zTemperature unit: Centigrade or Fahrenheit
zDisplay of memory: last ten memories
zLow voltage warning: the LCD displayand then a beep sound is heard
Power consumption:3 million watt in measurement mode
Battery cover |
Battery:two 1.5 V alkalescence batteries (AAA)
Battery life:4000 takes
Dimension:140×80×40mm
Net weight:Approx. 50g
Beeper sign:ON/OFF, measuring finish and low voltage warning, etc
Self-testing sequence:press the“ON/OFF” button to turn on the thermometer and all of symbol(see Fig A)
should be displayed on the LCD in one second.
Calibration frequency:two years, please done it by local Supervision bureau.
Manufacturing and Calibration date:See the label in the batteries box(open the batteries cover )
cautions:
1 Before measuring, the thermometer shall be stabilized at least 30 min under operating condition
2New Disposable probe cover required for each measurement, otherwise inaccurate readings will occur.
3 Please keep your ear canal clear, if not ,the measuring result shall be inaccurate.
4 the symbolon the LCD shows you can measure in the ear
5 Please don’t scratch the probe membrane, if not the thermometer shall lose the efficacy
6 if the LCD no changes under pressing any button, please take the batteries out and put in again
7 Please don’t use the thermometer if your ear canal has been inflammation
*The best choice for measurement the ear temperature and forehead temperature.
1. Press the on/off key for 5S when it power off, enter the measurement change mode.
2.Press the M key to change
3.When it finished,press the on/off key for restart
* It has a wider temperature measurement(5℃-75℃; 66.6℉-192.6℉)
Press the on/off key to displayand close up an object to measured.
How to use(℃displays for example)(Press the M key for 5S when it power off, then press M key again to change C or F
Measuring human body temperature in the Ear Cannal
1 Press the On/OFF button to turn on the thermometer, a beep sound is heard and the LCD displays as Fig a in
one second, then display the last memory one second as Fig b .When the LCD displays as Fig c ,now ready to
measure
2 Straighten the ear canal by pulling the outer ear up and back to give a clear view of the eardrum
3 While pulling the outer ear, insert the probe snugly into the ear canal (best to insert deep), press the scan/M
button, release it .When you hear a beep sound, the measurement is complete. Then remove the thermometer
from the ear. The display show the measure temperature (Fig d)
4 measuring again: If measuring again, please unclench the scan/M button and wait for the symbolto
display, then press scan/M button to measure again .(note: The time between each reading should be not less
than 1 min)
5 Memory search and change C/F: Press the scan/M button one second, the last ten memories(No9-No 0) will
take turns to display on the LCD as Fig E. Press the scan/M button three second ,will change C or F
6 The LCD will displays Err as Fig F and can not displays temperature when the ambient temperature is out of
the range of 10~40℃
Note: Before measuring, the thermometer shall be stabilized at the operating ambient condition for a
minimum of 30 min.
7 Shut off: Press ON/OFF button to shut off the thermometer or shall automatically shut off without
manipulating in 1 min)
Cleaning and Storage
1 Store thermometer in a dry location free from dust and contamination and away from direct sunlight .The
ambient temperature at the storage location should remain fairly constant and within the range of -25℃~55℃
2 use an alcohol swab or cotton swab moistened with alcohol (70% isopropyl) to clean the thermometer casing
and the measuring probe. Ensure that no liquid enters the interior of the thermometer.
3 Never use abrasive cleaning agents, thinners of gasoline for cleaning and never immerse the instrument in
water or other cleaning liquids. Take care not to scratch the surface of the probe membrane or display
Replacing the batteries
1 When voltage of the batteries is low, the LCD will displaysymbol, please replace two new batteries in
unit. The thermometer can not word accurately under the condition of low voltage
2 The thermometer is supplied with two 1.5V ALKALESCENCE BATTERIES (AAA).Insert new batteries when
the low voltage symbol appears on the LCD.
3 Remove the battery cover and take out the old batteries
4 Place two new batteries according to the “+” or “-“
5 Please take out the batteries to avoid battery leaking if unit not used for over six months.
6 The disposal of the probe cover, battery and device shall comply with the local environment requirements.
Quality warranty
This thermometer is guaranteed for one year under proper use according the operating manual from the date
that the product is sent out the factory